Source: Digilent Pmod Interface Specification 1.2.0 (revised 2017-10-05), retrieved 2026-07-12. These notes resolve the platform's open PMOD questions against the actual document; cite this file, not memory, in module reviews.

Pin numbering and orientation — VERIFIED#

Mechanical — resolves rev-A host decisions#

Electrical#

Interface type numbers (1.2.0 — supersedes older 1.1.0 numbering)#

TypeInterfacePins 1-4 (upper row)
1 / 1AGPIOIO1..IO4 (PWM on 2, and 8 for 1A)
2 / 2ASPICS, MOSI, MISO, SCK (+7 INT, 8 RESET, 9/10 CS2/3)
3 / 3AUARTCTS, TXD, RXD, RTS (+7 INT, 8 RESET)
4H-BridgeDIR, EN, SA, SB
5 / 5ADual H-BridgeDIR1, EN1, (S1A, S1B) / +7-10 DIR2, EN2, S2A, S2B
6I2CNC(INT), NC(RESET), SCL, SDA
7I2S codecLRCLK, DAC data, ADC data, BCLK (+9 MCLK option)

Platform corrections applied 2026-07-12: UART modules relabeled Type 4→3 (axs-024/025/044/046); I2S mics realigned to Type 7 (axs-028/029: 1 WS, 3 SD, 4 SCK — was a custom map). The audio-out module (axo-011) must use Type 7's DAC-data slot (pin 2) when designed.